REFRIGERATION COMPRESSORS
CHINTAMANI CH 5 SERIES
HEAVY DUTY Refrigeration COMPRESSOR
Technical Specification
| Compressor Model |
Cylinder
arrange
ment |
No of cylinders |
Cylinderbore |
Piston stroke |
Swept volume
1400 rpm |
Direction of rotation |
Discharge pressure |
Oil charge |
cooling waterflow |
Weight of compressor |
| |
|
|
mm |
mm |
m3/hr |
|
bar |
Ltrs |
LPM |
Kg |
|
CH 5
|
Vertical |
2 |
110 |
85 |
140.7 |
Anti Clockwise from Flywheel |
18.5 |
8 |
8 LPM for water Temp 30°C & 15 LPM for water temp 40°C |
255 |
Model CH 5 Regrigerant R22
|
Q [kW] |
Pe [kW] |
Tevap |
30 |
35 |
40 |
45 |
30 |
35 |
40 |
45 |
[°C] |
[°C] |
[°C] |
[°C] |
[°C] |
[°C] |
[°C] |
[°C] |
[°C] |
10 |
169.03 |
161.80 |
153.46 |
145.05 |
30.41 |
33.60 |
37.00 |
39.97 |
7 |
152.77 |
145.56 |
137.57 |
129.72 |
29.68 |
33.01 |
35.93 |
37.66 |
5 |
142.56 |
135.51 |
127.83 |
120.35 |
29.27 |
32.57 |
35.20 |
36.35 |
3 |
132.82 |
126.03 |
118.70 |
111.58 |
28.90 |
32.07 |
34.45 |
35.19 |
1 |
123.50 |
117.05 |
110.11 |
103.36 |
28.55 |
31.51 |
33.66 |
34.13 |
-1 |
114.60 |
108.54 |
102.01 |
95.62 |
28.19 |
30.88 |
32.82 |
33.15 |
-3 |
106.09 |
100.47 |
94.36 |
88.31 |
27.80 |
30.18 |
31.93 |
32.22 |
-5 |
97.97 |
92.79 |
87.10 |
81.40 |
27.38 |
29.41 |
30.98 |
31.30 |
-7 |
90.22 |
85.49 |
80.22 |
74.85 |
26.91 |
28.56 |
29.97 |
30.37 |
-9 |
82.85 |
78.56 |
73.68 |
68.63 |
26.37 |
27.64 |
28.91 |
29.42 |
-11 |
75.87 |
71.98 |
67.46 |
62.72 |
25.77 |
26.66 |
27.78 |
28.41 |
-13 |
69.29 |
65.75 |
61.55 |
57.10 |
25.09 |
25.63 |
26.61 |
27.34 |
-15 |
63.14 |
59.87 |
55.94 |
51.76 |
24.34 |
24.56 |
25.40 |
26.19 |
-17 |
57.45 |
54.36 |
50.62 |
46.70 |
23.51 |
23.47 |
24.17 |
24.94 |
-19 |
52.24 |
49.22 |
45.61 |
41.92 |
22.61 |
22.36 |
22.92 |
23.59 |
-21 |
47.57 |
44.49 |
40.91 |
37.43 |
21.65 |
21.27 |
21.67 |
22.13 |
-23 |
43.47 |
40.19 |
36.55 |
33.25 |
20.63 |
20.22 |
20.45 |
20.55 |
-25 |
40.01 |
36.35 |
32.54 |
29.40 |
19.56 |
19.23 |
19.28 |
18.86 |
-27 |
37.24 |
33.02 |
28.92 |
25.91 |
18.47 |
18.32 |
18.17 |
17.06 |
-29 |
35.23 |
30.25 |
25.73 |
22.82 |
17.36 |
17.54 |
17.17 |
15.15 |
-31 |
34.05 |
28.09 |
23.01 |
20.17 |
16.25 |
16.91 |
16.29 |
13.14 |
Model CH 5 Regrigerant NH3
|
Q [kW] |
Pe [kW] |
Tevap |
30 |
35 |
40 |
45 |
30 |
35 |
40 |
45 |
[°C] |
[°C] |
[°C] |
[°C] |
[°C] |
[°C] |
[°C] |
[°C] |
[°C] |
10 |
174.37 |
179.76 |
175.04 |
167.63 |
23.35 |
27.81 |
32.01 |
36.24 |
7 |
161.28 |
161.88 |
156.52 |
150.20 |
24.17 |
28.05 |
31.66 |
35.50 |
5 |
152.05 |
150.34 |
144.77 |
138.87 |
24.49 |
28.02 |
31.26 |
34.83 |
3 |
142.61 |
139.17 |
133.55 |
127.88 |
24.65 |
27.85 |
30.73 |
34.04 |
1 |
133.12 |
128.44 |
122.89 |
117.31 |
24.64 |
27.55 |
30.09 |
33.15 |
-1 |
123.73 |
118.19 |
112.81 |
107.22 |
24.48 |
27.13 |
29.36 |
32.16 |
-3 |
114.57 |
108.46 |
103.32 |
97.66 |
24.16 |
26.59 |
28.53 |
31.09 |
-5 |
105.76 |
99.26 |
94.40 |
88.67 |
23.71 |
25.95 |
27.64 |
29.97 |
-7 |
97.41 |
90.60 |
86.05 |
80.29 |
23.12 |
25.23 |
26.68 |
28.80 |
-9 |
89.62 |
82.48 |
78.24 |
72.52 |
22.41 |
24.42 |
25.69 |
27.60 |
-11 |
82.46 |
74.88 |
70.92 |
65.37 |
21.60 |
23.56 |
24.67 |
26.41 |
-13 |
76.03 |
67.79 |
64.05 |
58.84 |
20.68 |
22.66 |
23.63 |
25.23 |
-15 |
70.37 |
61.15 |
57.56 |
52.91 |
19.69 |
21.73 |
22.61 |
24.08 |
-17 |
65.54 |
54.92 |
51.36 |
47.55 |
18.62 |
20.78 |
21.62 |
23.00 |
-19 |
61.58 |
49.03 |
45.39 |
42.70 |
17.50 |
19.84 |
20.68 |
22.00 |
-21 |
58.51 |
43.42 |
39.53 |
38.33 |
16.34 |
18.93 |
19.80 |
21.10 |
-23 |
56.35 |
38.00 |
33.68 |
34.36 |
15.16 |
18.06 |
19.02 |
20.33 |
-25 |
55.10 |
32.66 |
27.71 |
30.72 |
13.98 |
17.26 |
18.35 |
19.73 |

Note: We reserve the right to modify the specifications in accordance with improved designs. Although every effort has been made to maintain accuracy in the data given, the figures are in no way binding.
Q: cooling capacity [kW]; Pe: compressor brake power [kW]
The chart rating is for maximum speed: 1000 rpm; Minimum speed allowed: 400 rpm
The capacity and power consumption ratings are possible by interpolation for other speed conditions.
The motor power is 10% over the compressor brake power
DTSC :0°C; DTSC:50C
Warranty : Every compressor carries a standard warranty against manufacturing defects of 12 months from date of startup / commissioning by CTTPL authorised engineer or 18 months from date of dispatch whichever occurs early. The warranty card must be produced for warranty claims. Standard warranty does not contain consumables like oil, oil filter, gaskets, o-ring etc and warranty is not applicable if failure occurs due to fault in system design.